CORE SERIES OVERVIEW
Amplifier Specifications
Product Model
FFA-4004
FFA-6004
FFA-8004
FFA-6000
FFA-8000
FFA-10000
Power Ratings Per Channel (RMS)
Measured per channel, driven at 1 kHz sine wave, 240 VAC mains supply voltage to no more than 1% TH
Load:
8 ohms
600 W
900 W
1000 W
1000 w
1250 w
1500 w
4 ohms
1000 W
1500 W
2000 W
1800 w
2400 w
3000 w
2 ohms
N/A
N/A
N/A
3000 W
4000 W
5000 W
Product Range
Models
Datasheet
FFA 4004
FFA four channel amplifiers
FEATURES AT A GLANCE
• Power efficient and cool running
• Rugged Tour class Aluminium construction
• Light weight – 9 kg
• FFA Class D technology
• High current switch mode power supply
• Side chain TCA clip limiter
• Hand built and designed in England
• Bi amp Neutrik® speakON outputs
• Signal Link through
• Neutrik® powerCON power input
• PSU soft start
• Analog filter option card with limiter threshold and delay –
ideal for stage monitor systems
• 5 year factory warranty
Specifications
FFA 4004
| Power Ratings | 4 x 600W @ 8 Ohm, 4 x 1000W @ 4 Ohm |
| Gain | 32 dB |
| THD | Typical 0.05 4 Ohm 1 kHz THD+N |
| Frequency Response | 20Hz • 20kHz ± 0.5dB |
| Controls | 40 Point Potentiometer per channel, power on switch |
| Indicators | Signal green = -20dB, signal yellow = -3dB, red signal = clip limiter, signal red protect = over current, low AC mains or 3 sec. mute on power up |
| Load Protection | DC on output, side chain TCA clip limiter circuit |
| Amplifier Protection | Short circuit, current overload, thermal shutdown, high frequency stability circuit |
| Audio Signal Inputs | Balanced Neutrik® Female XLR input connected Pin 1 – GND, Pin 2 – Hot +, Pin 3 – Cold -. XLR Male signal throughput each channel |
| Audio Signal Outputs | Neutrik® speakON each channel. Channels 1 and 3 output speakON utilises 2+ and 2- connection to allow use of 4 core loudspeaker cable for bi amp loudspeaker system for example stage monitor system |
| Power Requirement | 1 x Neutrik® 20A powerCON connector 1 x 16A 240 VAC Circuit. Power range 185V-240VAC |
| System Cooling | High CFM 80mm fan with proportional signal speed control. Rear to front airflow |
| Dimensions | 88mm Height x 483mm Width x 510mm Depth. Includes rear rack support. 19″ rack mount enclosure |
| Weight | 9 kg |
Datasheet
FFA 6004
FFA four channel amplifiers
FEATURES AT A GLANCE
• Power efficient and cool running
• Rugged Tour class Aluminium construction
• Light weight – 10 kg
• FFA Class D technology
• High current switch mode power supply
• Side chain TCA clip limiter
• Hand built and designed in England
• Bi amp Neutrik® speakON outputs
• Signal Link through
• Neutrik® powerCON power input
• PSU sof t start
• Analog filter option card with limiter threshold and delay –
ideal for stage monitor systems
• 5 year f actory warranty
Specifications
FFA 6004
| Power Ratings | 4 x 800W @ 8 Ohm, 4 x 1500W @ 4 Ohm |
| Gain | 32 dB |
| THD | Typical 0.05 4 Ohm 1 kHz THD+N |
| Frequency Response | 20Hz • 20kHz ± 0.5dB |
| Controls | 40 Point Potentiometer per channel, power on switch |
| Indicators | Signal green = -20dB, signal yellow = -3dB, red signal = clip limiter, signal red protect = over current, low AC mains or 3 sec. mute on power up |
| Load Protection | DC on output, side chain TCA clip limiter circuit |
| Amplifier Protection | Short circuit, current overload, thermal shutdown, high frequency stability circuit |
| Audio Signal Inputs | Balanced Neutrik® Female XLR input connected Pin 1 – GND, Pin 2 – Hot +, Pin 3 – Cold -. XLR Male signal throughput each channel |
| Audio Signal Outputs | Neutrik® speakON each channel. Channels 1 and 3 output speakON utilises 2+ and 2- connection to allow use of 4 core loudspeaker cable for bi amp loudspeaker system for example stage monitor system |
| Power Requirement | 1 x Neutrik® 20A powerCON connector 1 x 16A 240 VAC Circuit. Power range 185V-240VAC |
| System Cooling | High CFM 80mm fan with proportional signal speed control. Rear to front airflow |
| Dimensions | 88mm Height x 483mm Width x 510mm Depth. Includes rear rack support. 19″ rack mount enclosure |
| Weight | 10 kg |
Datasheet
FFA 8004
FFA four channel amplifiers
FEATURES AT A GLANCE
• Exceptional sound quality
• G2 DSP option
• High Power efficiency and cool running
• Rugged Tour class Aluminium construction
• Light weight – 10 kg
• FFA Class D PWM
• High current switch mode power supply designed to give
continuous power
• Superb limiter
• 4 XLR analogue audio inputs
• 4 XLR parallel outputs
• Bi amp Neutrik® speakON outputs
• Signal Link through
• Neutrik® powerCON power input
• PSU soft start
• Hand built & designed in Hertfordshire, England
• 5 year factory warranty
Specifications
FFA 8004
| Power Ratings | 4 x 1000W @ 8 Ohm, 4 x 2000W @ 4 Ohm |
| Gain | 32 dB |
| THD | Typical 0.05 4 Ohm 1 kHz THD+N |
| Frequency Response | 20Hz • 20kHz ± 0.5dB |
| Controls | 40 Point Potentiometer per channel, power on switch |
| Indicators | Signal green = -20dB, signal yellow = -3dB, red signal = clip limiter, signal red protect = over current, low AC mains or 3 sec. mute on power up |
| Load Protection | DC on output, side chain TCA clip limiter circuit |
| Amplifier Protection | Short circuit, current overload, thermal shutdown, high frequency stability circuit |
| Audio Signal Inputs | Balanced Neutrik® Female XLR input connected Pin 1 – GND, Pin 2 – Hot +, Pin 3 – Cold -. XLR Male signal throughput each channel |
| Audio Signal Outputs | Neutrik® speakON each channel. Channels 1 and 3 output speakON utilises 2+ and 2- connection to allow use of 4 core loudspeaker cable for bi amp loudspeaker system for example stage monitor system |
| Power Requirement | 1 x Neutrik® 20A powerCON connector 1 x 16A 240 VAC Circuit. Power range 185V-240VAC |
| System Cooling | High CFM 80mm fan with proportional signal speed control. Rear to front airflow |
| Dimensions | 88mm Height x 483mm Width x 510mm Depth. Includes rear rack support. 19″ rack mount enclosure |
| Weight | 10 kg |
Datasheet
FFA 6000
FFA four channel amplifiers
ldeally suited for driving very high output bass and sub bass loud speakers or high power full range systems. Designed to drive sustained, very high output audio into 2 Ohm loads.
The FFA-6000 features proprietary Class D PWM amplifier technology, partnered with FFA high-current switch-mode PSU. Massive bulk storage capacitance per channel ensures continuous high power delivery to the load. The FFA-6000 is designed as a dual-mono unit, with each channel totally independent. This amplifier is highly power-efficient and operates cool even in the most demanding environments. Its tour-grade mechanical construction uses aluminium throughout the chassis, providing a robust and rigid yet lightweight housing for the electronic systems.
FEATURES AT A GLANCE
• FFA Class D PWM amplifiers
• Power supply soft start
• High thermalheadroom
• Weight – 12kg
• Dual mono power amplifiers
• Clip limiter
• 5 year factory warranty
• Switch mode power supply
• Power efficient
• 2 Ohm drive
• All aluminium construction
• Dual power supply
• High current Neutrik® speakON® NL4MP-UC connectors
• Hand constructed and designed in England
Specifications
FFA 6000
| Power Ratings | 1000W @ 8 Ohms, 1800W @ 4 Ohms, 3000W @ 2 Ohms |
| Gain | 32 dB |
| THD | Typical 0.05 4 Ohm 1 kHz THD+N |
| Frequency Response | 20Hz – 20kHz |
| Controls | Power on rocker switch each channel. 40 point Potentiometer each channel |
| Indicators | Power ‘on’ green LED each channel, Signal present green LED, -3dB drive yellow LED, amplifier clip – red signal LED, amplifier protect due to over temp/clip limiter activated and 3 second mute at power up = red LED |
| Load Protection | DC on output, clip limiter |
| Amplifier Protection | Short circuit, current overload, thermal, reactive load stability |
| Audio Signal Inputs | Neutrik® female XLR with male XLR signal link through per channel |
| Audio Signal Outputs | Pair of Neutrik® NL4MP-UC speakON® connectors per channel. Each connector has all output poles live 1+, 1-, 2+, 2-. This allows the use of 4 core loudspeaker cable to minimise conductor losses between amplifier and loudspeaker |
| Power Supply | 2 x 20A Neutrik® powerCON® required – one each channel |
| System Cooling | 80mm variable speed high CFM fan. Rear to front air flow |
| Dimensions | 2RU 19″ rack mount enclosure, H88mm x W483mm x D510mm. Depth includes integral rear rack support ears |
| Weight | 12 kg |
| Power Requirement | 220-240 VAC 50-60Hz, 2x16A max per amplifier. Power range 185V-240VAC |
Datasheet
FFA 8000
FFA four channel amplifiers
ldeally suited for driving very high output bass and sub bass loud speakers or high power full range systems. Designed to drive sustained, very high output audio into 2 Ohm loads.
The FFA-8000 features proprietary Class D PWM amplifier technology, partnered with FFA high-current switch-mode PSU. Massive bulk storage capacitance per channel ensures continuous high power delivery to the load. The FFA-8000 is designed as a dual-mono unit, with each channel totally independent. This amplifier is highly power-efficient and operates cool even in the most demanding environments. Its tour-grade mechanical construction uses aluminium throughout the chassis, providing a robust and rigid yet lightweight housing for the electronic systems.
FEATURES AT A GLANCE
• FFA Class D PWM amplifiers
• Power supply soft start
• High thermal headroom
• Weight – 12kg
• Dual mono power amplifiers
• Clip limiter
• 5 year factory warranty
• Switch mode power supply
• Power efficient
• 2 Ohm drive
• All aluminium construction
• Dual power supply
• High current Neutrik® speakON® NL4MP-UC connectors
• Hand constructed and designed in England
Specifications
FFA 8000
| Power Ratings | 1250W @ 8 Ohms, 2400W @ 4 Ohms, 4000W @ 2 Ohms |
| Gain | 32 dB |
| THD | Typical 0.05 4 Ohm 1 kHz THD+N |
| Frequency Response | 20Hz – 20kHz |
| Controls | Power on rocker switch each channel. 40 point Potentiometer each channel |
| Indicators | Power ‘on’ green LED each channel, Signal present green LED, -3dB drive yellow LED, amplifier clip – red signal LED, amplifier protect due to over temp/clip limiter activated and 3 second mute at power up = red LED |
| Load Protection | DC on output, clip limiter |
| Amplifier Protection | Short circuit, current overload, thermal, reactive load stability |
| Audio Signal Inputs | Neutrik® female XLR with male XLR signal link through per channel |
| Audio Signal Outputs | Pair of Neutrik® NL4MP-UC speakON® connectors per channel. Each connector has all output poles live 1+, 1-, 2+, 2-. This allows the use of 4 core loudspeaker cable to minimise conductor losses between amplifier and loudspeaker |
| Power Supply | 2 x 20A Neutrik® powerCON® required – one each channel |
| System Cooling | 80mm variable speed high CFM fan. Rear to front air flow |
| Dimensions | 2RU 19″ rack mount enclosure, H88mm x W483mm x D510mm. Depth includes integral rear rack support ears |
| Weight | 12 kg |
| Power Requirement | 220-240 VAC 50-60Hz, 2x16A max per amplifier. Power range 185V-240VAC |
Datasheet
FFA 10000
FFA four channel amplifiers
ldeally suited for driving very high output bass and sub bass loud speakers or high power full range systems. Designed to drive sustained, very high output audio into 2 Ohm loads.
The FFA-10000 features proprietary Class D PWM amplifier technology, partnered with FFA high-current switch-mode PSU. Massive bulk storage capacitance per channel ensures continuous high power delivery to the load. The FFA-10000 is designed as a dual-mono unit, with each channel totally independent. This amplifier is highly power-efficient and operates cool even in the most demanding environments. Its tour-grade mechanical construction uses aluminium throughout the chassis, providing a robust and rigid yet lightweight housing for the electronic systems.
FEATURES AT A GLANCE
• FFA Class D PWM amplifiers
• Power supply soft start
• High thermal headroom
• Weight – 12kg
• Dual mono power amplifiers
• Clip limiter
• 5 year factory warranty
• Switch mode power supply
• Power efficient
• 2 Ohm drive
• All aluminium construction
• Dual power supply
• High current Neutrik® speakON® NL4MP-UC connectors
• Hand constructed and designed in England
Specifications
FFA 10000
| Power Ratings | 1500W @ 8 Ohms, 3000W @ 4 Ohms, 5000W @ 2 Ohms |
| Gain | 32 dB |
| THD | Typical 0.05 4 Ohm 1 kHz THD+N |
| Frequency Response | 20Hz – 20kHz |
| Controls | Power on rocker switch each channel. 40 point Potentiometer each channel |
| Indicators | Power ‘on’ green LED each channel, Signal present green LED, -3dB drive yellow LED, amplifier clip – red signal LED, amplifier protect due to over temp/clip limiter activated and 3 second mute at power up = red LED |
| Load Protection | DC on output, clip limiter |
| Amplifier Protection | Short circuit, current overload, thermal, reactive load stability |
| Audio Signal Inputs | Neutrik® female XLR with male XLR signal link through per channel |
| Audio Signal Outputs | Pair of Neutrik® NL4MP-UC speakON® connectors per channel. Each connector has all output poles live 1+, 1-, 2+, 2-. This allows the use of 4 core loudspeaker cable to minimise conductor losses between amplifier and loudspeaker |
| Power Supply | 2 x 20A Neutrik® powerCON® required – one each channel |
| System Cooling | 80mm variable speed high CFM fan. Rear to front air flow |
| Dimensions | 2RU 19″ rack mount enclosure, H88mm x W483mm x D510mm. Depth includes integral rear rack support ears |
| Weight | 12 kg |
| Power Requirement | 220-240 VAC 50-60Hz, 2x16A max per amplifier. Power range 185V-240VAC |